Indoor Air Quality, Traffic Pollution Infiltration and Resource Adequacy in School Health Rooms in Bangkok
Keywords:
School health rooms, PM2.5, Polynomial regression, Resource adequacy, Healthcare personnel licensingAbstract
Environmental safety and resource adequacy within educational settings are pivotal to student healthcare and recovery. This study evaluates environmental factors—specifically particulate matter (PM2.5 and PM10), carbon dioxide (CO2), and meteorological parameters (temperature, relative humidity, and air velocity)—within school health rooms under the Bangkok Metropolitan Administration. Additionally, it examines the spatial correlation between traffic-related pollutant infiltration and physical setback distances from major roadways, alongside an assessment of physical resource adequacy, focusing on the bed-to-student ratio and emergency medical equipment, such as Automated External Defibrillators (AEDs) and the professional licensing status of healthcare personnel. Using a cross-sectional descriptive design across eleven purposively selected schools, real-time monitoring via calibrated sensors and physical facility surveys were conducted. Polynomial regression analysis revealed a significant non-linear (curvilinear) relationship between setback distance and particulate matter infiltration, demonstrating that increased distance from arterial roads substantially mitigates PM2.5 (R2 » 0.72, power function) and PM10 (R2 » 0.59, linear function) concentrations. Conversely, indoor CO2 levels exhibited no spatial correlation with roadways but frequently accumulated inside due to occupancy density and inadequate air exchange. Preliminary compliance and physical resource benchmarking indicated that while meteorological conditions generally aligned with comfort criteria, PM2.5 concentrations frequently breached national safety thresholds. Furthermore, a critical disparity was identified in facility and personnel preparedness: the bed-to-student ratios across most schools fell significantly below optimal recovery standards, and the deployment of life-saving AED units remained critically inconsistent. Crucially, the human resource evaluation revealed that while 60% of the sampled schools employed dedicated health room staff, only half of these personnel (30% of the total sample) possessed official professional licenses, while the remaining half (30% of the total sample) were unlicensed, with 40% of the schools completely lacking designated healthcare staff. These comprehensive findings provide a data-driven framework for policy-makers and architects to establish standardized guidelines that integrate environmental mitigation, spatial site-planning, and emergency resource allocation to secure safe educational recovery environments.